• FirePro® CF Fire Protection Systems

Fire protection solution for upgrading timber floors

Categories: ,
  1. General Details

    As  part  of the comprehensive FirePro® range of fire protection products, FirePro® CF Fire Protection Systems provides a method of increasing the fire resistance of timber compartment floors without the need of removing ceilings.

    Tested to BS 476 Part 21, FirePro® CF Fire Protection Systems provide up to 2 hours fire protection.

     

    Advantages

    • Suitable for upgrading fire rating of heritage buildings
    • Lightweight solution
    • Fire rated up to 2 hours
    • Load bearing capacity
    • Integrated fire rated penetration seals
    • Fast and easy installation solution
    • Improved acoustic performance
  2. Technical Info

    Load bearing capacity

    The FirePro® CF Fire Protection System has been tested for a load bearing capacity  of 1.6kN/m² for up to 135 minutes or 2.35kN/m² for up to 108 minutes when tested in accordance with BS 476 Part 21.

    Fire rating

    Timber floors must be supported from appropiate masonry/concrete or steel constructions that have at least the fire resistance required for the floors to BS476 Part 21/22 and are capable of providing adequate support to the constructions for the required period of fire resistance.

    The construction and loading of timber floors must comply with BS 5268 Part 2.

    The FirePro® CF Fire Protection System has been tested for up to 2 hours to BS 476 Part 21.

     

  3. Order Enquiry

    Contact form description text

    • 2 + 32 =
  4. Product Video
  5. Documents